TM 9-2320-365-20-3 8-14. TRANSMISSION OIL COOLER HOSES INITIAL INSTALLATION (CONT) WARNING Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well- ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (12) Apply antiseize compound to threads of 45-degree fitting (20). (13) Install 45-degree fitting (20) on transmission oil cooler hose (19). (14) Connect transmission oil sampling hose (21) to 45- degree fitting (20). (15) Connect transmission oil sampling hose (21) to transmission oil sampling valve (2). 8-58 Change 1