TM 9-2320-365-20-3 b. WTEC III TPSS Calibration. NOTE WTEC III TPSS requires calibration after installation. Calibration is accomplished in steps (1) through (4). (1) Position master power switch to on and wait for neutral (N) indication from WTEC III TPSS (TM 9-2320-365-10). (2) Position master power switch to off (TM 9-2320-365-10). (3) Perform steps (1) and (2) four more times. (4) Position master power switch to on (TM 9-2320-365-10). (5) Start engine (TM 9-2320-365-10). (6) Check VOLTS gage for charge indication (TM 9-2320- 365-10). NOTE Transmission shifting may be rough until WTEC III TPSS determines proper shift points. Operating vehicle through each gear range several times will allow WTEC III TPSS to determine proper shift points. (7) Test drive vehicle and check operation of vehicle through all gear ranges several times (TM 9-2320-365-10). (8) Shut down engine (TM 9-2320-365-10). End of Task. 8-31