TM 9-2320-365-20-3 c. Exiting the Diagnostic Display Mode. (1) Exit the diagnostic display mode by any of the following methods. (a) Press (1) and (2) (up arrow and down arrow) buttons on WTEC II TEPSS (3) at the same time. (b) Press any range button (4), D, N, or R on WTEC II TEPSS (3) (the shift will be commanded if not inhibited by an active code). (c) Wait until the calibrated time (approximately 10 minutes) has passed and system automatically returns to the normal operating mode. (d) Position master power switch to off (TM 9-2320-365- 10). e. Follow-On Maintenance. Perform Transmission System Troubleshooting (para 2-17). End of Task. 8-13