Page 617 of 1268

TM 9-2320-365-20-3 NOTE • Both clamps are installed the same way. One shown. • Install plastic cable ties as required. (3) Position starter to shunt 24 vdc cable (1) in clamp (6). (4) Position clamp (6) on frame rail (7) with screw (8) and self-locking nut (9). (5) Perform steps (3) and (4) on remaining clamp. NOTE Step (6) requires the aid of an assistant. (6) Tighten two self-locking nuts (9) to 96-120 lb-in. (11-14 N·m). (7) Position terminal lugs TL46 (10) and TL25 (11) on starting motor terminal (12) with nut (13). (8) Tighten nut (13) to 15-20 lb-ft (20-27 N m). WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (9) Apply adhesive to terminal lugs TL46 (10) and TL25 (11) and nut (13). Change 1 7-363