TM-9-2320-365-20-3 LMTV Unit Maintenance Manual M1078 Series - Volume 3 Download

Page 606 of 1268

TM 9-2320-365-20-3 7-82. START AND CHARGING CABLE ASSEMBLY REPLACEMENT (CONT) (16) Install terminal lugs TL33 (23) and TL23 (24) on auxiliary starter solenoid (20) with two lockwashers (25) and nuts (26). WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (17) Apply adhesive to nuts (22 and 26). NOTE Perform steps (18) and (19) on vehicles equipped with 200 amp alternator. (18) Install terminal lug TL36 (27) on 200 amp terminal block terminal (28) with washer (29), lockwasher (30), and nut (31). (19) Tighten nut (31) to 16-18 lb-ft (21-25 N m). 7-352