TM 9-2320-365-20-3 7-80. 100 AMP REVERSE POLARITY RELAY TO POWER DISTRIBUTION PANEL (PDP) 12 VDC CABLE REPLACEMENT (CONT) (9) Install suspension compression plate (15) on suspension compression plate stud (16) with spring pin (17). (10) Install terminal lug TL80 (18) on 100 amp reverse polarity relay 12 vdc terminal (19) with lockwasher (20) and nut (21). (11) Position dust boot (22) on terminal lug TL80 (18). (12) Position intake air cleaner boot (23) on intake air cleaner housing (24) with clamp (25). (13) Tighten clamp (25) to 36-48 lb-in. (4-5 N·m). (14) Position air compressor intake hose (26) on intake air cleaner boot (23) with clamp (27). (15) Tighten clamp (25) to 36-48 lb-in. (4-5 N·m). (16) Lower cab (TM 9-2320-365-10). 7-334