TM 9-2320-365-20-3 7-80. 100 AMP REVERSE POLARITY RELAY TO POWER DISTRIBUTION PANEL (PDP) 12 VDC CABLE REPLACEMENT (CONT) (13) Loosen two screws (22) in heat shield assembly (23). (14) Remove 100 amp reverse polarity relay to PDP 12 vdc cable (24) from heat shield assembly (23). (15) Remove self-locking nut (25), screw (26), clamp (27), and 100 amp reverse polarity relay to PDP 12 vdc cable (24) from frame rail (28). Discard self-locking nut. (16) Remove 100 amp reverse polarity relay to PDP 12 vdc cable (24) from clamp (27). (17) Raise cab (TM 9-2320-365-10). (18) Remove self-locking nut (29), washer (30), screw (31), and washer (32) from clamps (33 and 34). (19) Remove 100 amp reverse polarity relay to PDP 12 vdc cable (24) from clamp (33). (20) Remove 100 amp reverse polarity relay to PDP 12 vdc cable (24) from cab (35). 7-332