TM-9-2320-365-20-3 LMTV Unit Maintenance Manual M1078 Series - Volume 3 Download
Page 509 of 1268
TM 9-2320-365-20-3 7-66. 100 AMP ALTERNATOR TO REVERSE POLARITY RELAY 24 VDC CABLE REPLACEMENT This task covers: a. Removal b. Installation c. Follow-On Maintenance INITIAL SETUP Equipment Conditions Spare tire lowered (TM 9-2320-365-10). Cab raised (TM 9-2320-365-10). Batteries disconnected (para 7-48). Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) Wrench, Torque, 0-175 lb-ft (Item 57, Appendix C) Wrench, Torque, 0-200 lb-in. (Item 58, Appendix C) Socket Set, Socket Wrench (Item 34, Appendix C) Materials/Parts Dispenser, Pressure Sensitive Adhesive Tape (Item 21, Appendix D) Ties, Cable, Plastic (Item 76, Appendix D) Lockwasher (Item 89, Appendix G) Nut, Self-Locking (Item 127, Appendix G) a. Removal. (1) Loosen clamp (1) on turbocharger intake hose (2). (2) Remove turbocharger intake hose (2) from intake air cleaner boot (3). (3) Lift terminal cover (4) on terminal lugs TL1 (5), TL36 (6), and TL37 (7). NOTE Remove plastic cable ties as required. (4) Remove nut (8), lockwasher (9), and terminal lugs TL1 (5), TL36 (6), and TL37 (7) from reverse polarity relay 24 VDC LOAD terminal (10). Discard lockwasher. 7-263