TM 9-2320-365-20-3 (5) Disconnect connector clamp (4) from connector P36 (5). (6) Disconnect water temperature switch connector (6) from connector P36 (5). (7) Remove water temperature switch (7) from upper coolant tube (8). b. Installation. (1) Install water temperature switch (1) in upper coolant tube (2). (2) Connect connector P36 (3) to water temperature switch connector (4). (3) Connect connector clamp (5) on connector P36 (3). 7-177