TM 9-2320-365-20-3 b. Installation. WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (1) Apply antiseize compound to threads of coolant temperature gage sensor (1). (2) Install coolant temperature gage sensor (1) in adapter (2). (3) Connect connector P41 (3) to coolant temperature gage sensor (1). c. Follow-On Maintenance. (1) Connect batteries (para 7-48). (2) Lower cab (TM 9-2320-365-10). (3) Start engine (TM 9-2320-365-10). (4) Check coolant temperature gage operation (TM 9-2320- 365-10). (5) Shut down engine (TM 9-2320-365-10). End of Task. Change 1 7-165