TM-9-2320-365-20-3 LMTV Unit Maintenance Manual M1078 Series - Volume 3 Download

Page 377 of 1268

TM 9-2320-365-20-3 (12) Remove six self-locking nuts (25), spring washers (26), screws (27), and 100 amp reverse polarity relay (9) from bracket (28). Discard spring washers and self-locking nuts. b. Installation. (1) Position 100 amp reverse polarity relay (1) on bracket (2) with six screws (3), spring washers (4), and self-locking nuts (5). (2) Tighten six screws (3) to 60-72 lb-in. (7-8 N·m). (3) Position terminal lugs TL36 (6), TL37 (7), and TL1 (8) on 100 amp reverse polarity relay (1) with lockwasher (9) and nut (10). (4) Tighten nut (10) to 120-144 lb-in. (14-16 N·m). (5) Position terminal cover (11) on terminal lugs TL36 (6), TL37 (7), and TL1 (8). (6) Install terminal lug TL80 (12) on 100 amp reverse polarity relay (1) with lockwasher (13) and nut (14). (7) Tighten nut (14) to 120-144 lb-in. (14-16 N·m). (8) Position dust boot (15) on terminal lug TL80 (12). 7-135