TM 9-2320-365-20-3 (5) Remove two screws (10) and bracket (8) from solenoid (11). (6) Remove 90-degree fitting (4) from solenoids (11). (7) Remove fitting (6) from solenoid (11). (8) Remove plug (12) from solenoid (11). b. Installation. WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (1) Apply antiseize compound to threads of plug (1), fitting (2), and 90-degree fitting (3). (2) Install plug (1) in solenoid (4). (3) Install fitting (2) in solenoid (4). (4) Install 90-degree fitting (3) in solenoid (4). (5) Install bracket (5) on solenoid (4) with two screws (6). 7-123