TM-9-2320-365-20-3 LMTV Unit Maintenance Manual M1078 Series - Volume 3 Download
Page 356 of 1268
TM 9-2320-365-20-3 7-19. START INHIBIT PUSHBUTTON SWITCH REPLACEMENT This task covers: a. Removal b. Installation c. Follow-On Maintenance INITIAL SETUP Equipment Conditions Batteries disconnected (para 7-48). PDP cover removed (para 16-2). Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) Materials/Parts Dispenser, Pressure Sensitive Adhesive Tape (Item 21, Appendix D) a. Removal. (1) Remove three screws (1) and washers (2) from PDP (3). (2) Remove three screws (4) from PDP (3). (3) Lift PDP (3) outward to gain access. NOTE Tag electrical connectors and connection points prior to disconnecting. (4) Disconnect terminal lugs TL158 (5) and TL159 (6) from start inhibit pushbutton switch (7). (5) Remove spring clip (8) and start inhibit pushbutton switch (7) from PDP (3). 7-114