TM-9-2320-365-20-3 LMTV Unit Maintenance Manual M1078 Series - Volume 3 Download
Page 354 of 1268
TM 9-2320-365-20-3 7-18. ROCKER SWITCHES REPLACEMENT (CONT) (8) Remove lamp base (8) from PTO switch (5). (9) Remove lamp (9) from lamp base (8). d. Auxiliary Panel Rocker Switch Installation. NOTE All auxiliary panel rocker switches are installed the same way. PTO switch shown. (1) Install lamp (1) in lamp base (2). (2) Install lamp base (2) in PTO switch (3). (3) Install PTO switch (3) in auxiliary panel (4). (4) Connect connector P903A (5) to PTO switch (3). (5) Connect connector P903 (6) to PTO switch (3). 7-112