TM-9-2320-365-20-3 LMTV Unit Maintenance Manual M1078 Series - Volume 3 Download

Page 329 of 1268

TM 9-2320-365-20-3 Change 2 7-87 b. Installation. (1) Remove cover (1) from speedometer (2). (2) Set dipswitches 3,6,7, and 9 in the down position. (3) Set dipswitches 1,2,4,5,8, and 10 in the up position. (4) Position speedometer (2) in instrument panel assembly (3) with retaining ring (4) and two self- locking nuts (5). (5) Tighten two self-locking nuts (5) to 9 lb-in. (1 N•m). (6) Install two protective caps (6) on speedometer (2). (7) Connect connector PX8 (7) on speedometer connector (8). (8) Connect connector clamp (9) on speedometer connector (8). c. Follow-On Maintenance. (1) Install instrument panel assembly (para 7-15). (2) Check gage(s) operation (TM 9-2320-365-10). End of Task. CAUTION Ensure dipswitch settings are correct. Failure to comply may result in inaccurate speedometer readings. NOTE Perform steps (1) through (3) on speedometer. NOTE Note position of speedometer prior to installation. NOTE Install plastic cable ties as required.