TM 9-2320-365-20-3 7-14. ELECTRICAL GAGES REPLACEMENT This task covers: a. Removal b. Installation c. Follow-On Maintenance INITIAL SETUP Equipment Conditions Instrument panel assembly removed for access (para 7-15). Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) Wrench, Torque, 0-75 lb-in. (Item 86, Appendix B) Materials/Parts Nut, Self-Locking (2) (Item 125, Appendix G) Ties, Cable, Plastic (Item 76, Appendix D) a. Removal. NOTE All electrical gages are removed the same way. Speedometer shown. (1) Disconnect connector clamp (1) from speedometer connector (2). NOTE Remove plastic cable ties as required. (2) Disconnect connector PX8 (3) from speedometer connector (2). NOTE Note position of speedometer prior to removal. (3) Remove two protective caps (4), self-locking nuts (5), retaining ring (6), and speedometer (7) from instrument panel assembly (8). Discard self-locking nuts. 7-86