TM-9-2320-365-20-3 LMTV Unit Maintenance Manual M1078 Series - Volume 3 Download

Page 211 of 1268

TM 9-2320-365-20-3 (7) Position upper coolant tube (8) between coolant hose (7) and thermostat housing (10). (8) Slide coolant hose (6) onto thermostat housing (10). (9) Engage as many clamp tabs (4) as possible in tab windows (5) allowing little or no play between four clamps and two coolant hoses (6 and 7). (10) Tighten four clamps (2) to 12-18 lb-in. (1-2 N·m). NOTE Minimum allowable gap on clamp is 0.2 in. (5 mm). If gap is less than 0.2 in. (5 mm), remove and re-install clamp. (11) Measure gap on four clamps (2). Change 1 6-53