TM-9-2320-365-20-3 LMTV Unit Maintenance Manual M1078 Series - Volume 3 Download

Page 195 of 1268

TM 9-2320-365-20-3 b. Installation. WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (1) Apply antiseize compound to threads of ether sensor (1). (2) Install ether sensor (1) in coolant bypass tube (2). NOTE Both coolant hoses are assembled the same way. Only one shown. (3) Loosen two screws (3) in clamps (4) and clamps (5) as far as possible without disengaging screws from D-nuts (6). (4) Unhook clamp tabs (7) from tab windows (8). 6-37