TM-9-2320-365-20-3 LMTV Unit Maintenance Manual M1078 Series - Volume 3 Download
Page 189 of 1268
TM 9-2320-365-20-3 (10) Connect compressor inlet coolant tube (10) to 90-degree fitting (6). (11) Install transmission oil cooler hose (11) on thermostat housing (4) with hose clamp (12). WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash with soap and water. Failure to comply may result in injury to personnel. (12) Apply antiseize compound to threads of water temperature light switch (13). (13) Install water temperature light switch (13) in thermostat housing (4). (14) Connect water temperature light switch connector (14) to connector P37 (15). (15) Connect connector clamp (16) on water temperature light switch connector (14). 6-31