TM 9-2320-365-20-3 6-6. THERMOSTAT HOUSING REPLACEMENT This task covers: a. Removal b. Installation c. Follow-On Maintenance INITIAL SETUP Equipment Conditions Thermostat removed (para 6-5). Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) Pan, Drain (Item 24, Appendix C) Goggles, Industrial (Item 15, Appendix C) Gloves, Rubber (Item 13, Appendix C) Materials/Parts Packing, Preformed (Item 178, Appendix G) Adhesive (Item 6, Appendix D) Antifreeze, Ethylene Glycol, Permanent (Item 13, Appendix D) Antiseize Compound (Item 63, Appendix D) a. Removal. (1) Position drain pan under thermostat housing (1). (2) Disconnect heater tube (2) from fitting (3). (3) Loosen hose clamp (4) on radiator fill hose (5). (4) Disconnect radiator fill hose (5) from fitting (6). (5) Disconnect connector clamp (7) from water temperature transducer connector (8). (6) Disconnect water temperature transducer connector (8) from connector P41 (9). (7) Remove water temperature transducer (10) from tee fitting (11). (8) Disconnect connector clamp (12) from water temperature light switch connector (13). (9) Disconnect water temperature light switch connector (13) from connector P37 (14). (10) Remove water temperature light switch (15) from thermostat housing (1). 6-28 Change 1