TM-9-2320-365-20-3 LMTV Unit Maintenance Manual M1078 Series - Volume 3 Download
Page 174 of 1268
TM 9-2320-365-20-3 6-4. RADIATOR FAN SHROUDS REPLACEMENT (CONT) (11) Apply sealing compound to threads of screw (14). (12) Install washer (15) and screw (14) on left side of top radiator fan shroud (2). (13) Tighten screw (14) to 84-108 lb-in. (10-12 N·m). (14) Position six washers (11), three screws (12), and self- locking nuts (13) on left side of top radiator fan shroud (2). (15) Tighten three self-locking nuts (13) to 84-108 lb-in. (10- 12 N·m). (16) Connect fan clutch hoses (9 and 16) to 90-degree fitting (5). (17) Install radiator vent hose (17) on radiator (18) with hose clamp (19). c. Bottom Radiator Fan Shroud Removal. (1) Position container under radiator (1). (2) Remove radiator cap (2) from radiator overflow tank (3). (3) Open radiator draincock (4) and drain coolant from radiator (1). (4) Close radiator draincock (4). 6-18 Change 1 WARNING Adhesive sealant MIL-S-46163 can damage your eyes. Wear safety goggles/glasses when using; avoid contact with eyes. If sealant contacts eyes, flush eyes with water and get immediate medical attention. Failure to comply may result in injury to personnel.