TM-9-2320-365-20-3 LMTV Unit Maintenance Manual M1078 Series - Volume 3 Download
Page 165 of 1268
TM 9-2320-365-20-3 (3) Remove two adapters (4) from radiator overflow tank (2). (4) Remove two sightglasses (5) from radiator overflow tank (2). c. Radiator Overflow Tank Assembly. WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (1) Apply antiseize compound to threads of two sightglasses (1) and adapters (2). (2) Install two sightglasses (1) in radiator overflow tank (3). (3) Install two adapters (2) in radiator overflow tank (3). 6-9