TM 9-2320-365-20-3 15-2.2 Change 2 15-2. RESILIENT MOUNT AND MECHANICAL STOP REPLACEMENT (CONT) e. Front Angle Bracket Resilient Mount Removal. Remove nut (1), spring washer (2), bolt (3), and resilient mount (4) from front angle bracket (5). Discard spring washer. f. Front Angle Bracket Resilient Mount Installation. (1) Position resilient mount (1) on front angle bracket (2) with bolt (3), spring washer (4), and nut (5). (2) Tighten nut (5) to 35-46 lb-ft (47-63 N•m). NOTE Left and right side front angle bracket resilient mounts are removed the same way. Right side shown. NOTE Left and right side front angle bracket resilient mounts are installed the same way. Right side shown.