TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1153 2-1153 2-1153 2-1153 2-1153 CONTINUITY TEST (1) Remove screw and cover from 110 vac outlet J233. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to supply pole of 110 vac receptacle J233. (4) Connect negative (-) probe of multimeter to supply socket of 110 vac receptacle J233 and note reading on multimeter. (5) Connect positive (+) probe of multimeter to neutral pole of 110 vac receptacle J233. (6) Connect negative (-) probe of multimeter to neutral socket of 110 vac receptacle J233 and note reading on multimeter. (7) Connect positive (+) probe of multimeter to ground pole of 110 vac receptacle J233. (8) Connect negative (-) probe of multimeter to ground socket of 110 vac receptacle J233 and note reading on multimeter. (9) If continuity is not present in steps (4), (6), and (8), replace 110 vac receptacle J233 (para 16-53).