TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1950 2-1950 2-1950 2-1950 2-1950 TEST OPTIONS KNOWN INFO 3. YES NO Winch Control Valve Fault Check REASON FOR QUESTION Is pressure totally absent at V1 and/or V2 on 11K self-recovery winch? A faulty electrical system or winch control valve will cause pressure to be absent at both ports on 11K self-recovery winch. Hydraulic oil level OK. Hydraulic tubes and fittings OK. Hydraulic rotary pump OK. 11K self-recovery winch OK. POSSIBLE PROBLEMS Faulty winch control valve. Faulty electrical supply/ control valve solenoid. Replace winch control valve (para 17-6). Perform Electrical System Troubleshooting (e85. Self- Recovery Winch Does Reel In or Pay Out). r1. 11K SELF-RECOVERY WINCH DOES NOT WORK (CONT) r1. 11K SELF-RECOVERY WINCH DOES NOT WORK (CONT) r1. 11K SELF-RECOVERY WINCH DOES NOT WORK (CONT) r1. 11K SELF-RECOVERY WINCH DOES NOT WORK (CONT) r1. 11K SELF-RECOVERY WINCH DOES NOT WORK (CONT)