TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 984 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1948 2-1948 2-1948 2-1948 2-1948 TEST OPTIONS 2. KNOWN INFO POSSIBLE PROBLEMS Winch Control Valve Pressure Test REASON FOR QUESTION YES NO Faulty 11K self-recovery winch. Faulty winch control valve. Faulty electrical supply/ control valve solenoid. Is pressure absent or below 2000 psi (13790 kPa) at V1 and/or V2 on 11K self-recovery winch? Faulty winch control valve will cause 11K self-recovery winch not to operate due to low or absent hydraulic pressure. Hydraulic oil level OK. Hydraulic tubes and fittings OK. Hydraulic rotary pump OK. Notify DS maintenance. r1. 11K SELF-RECOVERY WINCH DOES NOT WORK (CONT) r1. 11K SELF-RECOVERY WINCH DOES NOT WORK (CONT) r1. 11K SELF-RECOVERY WINCH DOES NOT WORK (CONT) r1. 11K SELF-RECOVERY WINCH DOES NOT WORK (CONT) r1. 11K SELF-RECOVERY WINCH DOES NOT WORK (CONT)