TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 982 of 1432
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2  2-1946 2-1946 2-1946 2-1946 2-1946  1.  TEST OPTIONS  REASON FOR QUESTION  YES  NO  START  KNOWN INFO  POSSIBLE PROBLEMS  Input Flow Test  Is hydraulic pressure  to winch control  valve OK?  WARNING  Read WARNING  on following page.  INITIAL SETUP  Equipment Conditions  Engine shut down (TM 9-2320-365-10).  Personnel Required  (2)  References  TM 9-4910-571-12&P  r1. 11K SELF-RECOVERY WINCH DOES NOT WORK  Hydraulic oil level OK.  Hydraulic tubes and fittings  OK.  Faulty hydraulic rotary  pump.  Faulty 11K self-recovery  winch.  Faulty winch control valve.  Faulty electrical supply/  control valve solenoid.  Faulty hydraulic rotary  pump will cause winch to  not operate.  Tools and Special Tools  Tool Kit, Genl Mech (Item 44, Appendix C)  STE/ICE-R (Item 39, Appendix C)  Pan, Drain (Item 24, Appendix C)  Transducer, STE/ICE-R (Item 1, Appendix J)  Goggles, Industrial (Item 15, Appendix C)  Materials/Parts  Rag, Wiping (Item 51, Appendix D)  Notify DS maintenance.