TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 90 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1144 2-1144 2-1144 2-1144 2-1144 TEST OPTIONS REASON FOR QUESTION KNOWN INFO Continuity Test or STE/ICE-R #91 6. POSSIBLE PROBLEMS Lighting fixtures DS80 and DS81 OK. Lighting fixture DS83 OK. Wire 706B OK. Wire 1499K OK. Faulty wire 3085AJ. Faulty lighting fixture DS82. Is continuity present on wire 3085B from 110/208 VAC POWER DISTRIBUTION PANEL to wire 3085AJ in lighting fixture DS82? YES NO If continuity is not present, wire 3085AJ is faulty. If continuity is present, lighting fixture DS82 is faulty. Repair or replace wire 3085AJ from lighting fixture DS83 to DS82 (para 2-40). Replace lighting fixture DS82 (para 16-59). e104. M1079 LIGHTING FIXTURE(S) DS82 AND/OR DS83 DO NOT OPERATE (CONT) e104. M1079 LIGHTING FIXTURE(S) DS82 AND/OR DS83 DO NOT OPERATE (CONT) e104. M1079 LIGHTING FIXTURE(S) DS82 AND/OR DS83 DO NOT OPERATE (CONT) e104. M1079 LIGHTING FIXTURE(S) DS82 AND/OR DS83 DO NOT OPERATE (CONT) e104. M1079 LIGHTING FIXTURE(S) DS82 AND/OR DS83 DO NOT OPERATE (CONT)