TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1143 2-1143 2-1143 2-1143 2-1143 CONTINUITY TEST (1) Disconnect AC power (TM 9-2320-365-10). (2) Remove six screws and cover from 110/208 VAC POWER DISTRIBUTION PANEL. (3) Loosen screw in terminal board TB4. (4) Remove wire 1499K from terminal board TB4. (5) Set multimeter to ohms. (6) Connect positive (+) probe of multimeter to wire 1499K in 110/208 VAC POWER DISTRIBUTION PANEL. (7) Connect negative (-) probe of multimeter to wire 1499K in lighting fixture DS82 and note reading on multimeter. (8) If continuity is not present, repair or replace wire 1499K from lighting fixture DS83 to DS82 (para 2-40).