TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 88 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1142 2-1142 2-1142 2-1142 2-1142 TEST OPTIONS REASON FOR QUESTION KNOWN INFO Continuity Test or STE/ICE-R #91 5. POSSIBLE PROBLEMS YES NO If continuity is not present, wire 1499K is faulty. Lighting fixtures DS80 and DS81 OK. Lighting fixture DS83 OK. Wire 706B OK. Is continuity present on wire 1499K from 110/208 VAC POWER DISTRIBUTION PANEL to lighting fixture DS82? Repair or replace wire 1499K from lighting fixture DS83 to DS82 (para 2-40). Faulty wire 1499K. Faulty wire 3085AJ. Faulty lighting fixture DS82. e104. M1079 LIGHTING FIXTURE(S) DS82 AND/OR DS83 DO NOT OPERATE (CONT) e104. M1079 LIGHTING FIXTURE(S) DS82 AND/OR DS83 DO NOT OPERATE (CONT) e104. M1079 LIGHTING FIXTURE(S) DS82 AND/OR DS83 DO NOT OPERATE (CONT) e104. M1079 LIGHTING FIXTURE(S) DS82 AND/OR DS83 DO NOT OPERATE (CONT) e104. M1079 LIGHTING FIXTURE(S) DS82 AND/OR DS83 DO NOT OPERATE (CONT)