TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 87 of 1432
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2  2-1141 2-1141 2-1141 2-1141 2-1141  CONTINUITY TEST  (1) Open door on 110/208 VAC POWER  DISTRIBUTION PANEL (TM 9-2320-365-10).  (2) Position circuit breaker CB1 to OFF  (TM 9-2320-365-10).  (3) Remove two screws and cover from  INTERIOR LIGHTS switch outlet box.  (4) Remove ballast cover from lighting fixture  DS82.  (5) Set multimeter to ohms.  (6) Connect positive (+) probe of multimeter to  bottom left pole of switch S32.  (7) Connect negative (-) probe of multimeter to  wire 706B in lighting fixture DS82 and note  reading on multimeter.  (8) If continuity is not present, repair or replace  wire 706B from lighting fixture DS83 to  DS82 (para 2-40).  (9) Install cover on INTERIOR LIGHTS switch  outlet box with two screws.  (10) Close door on 110/208 VAC POWER  DISTRIBUTION PANEL (TM 9-2320-365-10).