TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 829 of 1432
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1773 2-1773 2-1773 2-1773 2-1773 (1) Start engine (TM 9-2320-365-10) and operate at 1,000 RPM for five minutes. (2) Select an inflation mode at CTIS ECU and check if two steady mode light returns. (3) Apply and release brakes once or twice and check if pressure gages are slow to reach 120 psi. (4) If two steady mode lights remain illuminated and brake air pressure gages are slow to reach 120 psi, Perform Air System Troubleshooting (j1. Air System Loses Pressure During Operation). (5) Shut down engine (TM 9-2320-365-10).