TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1770 2-1770 2-1770 2-1770 2-1770 NO YES 2. Two steady mode lights illuminate during inflation. Soapy Water Leak Test KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION Are air hoses from wet tank to manifold valve assembly free from leaks? Steady Mode lights may light if an air leak is present. Faulty air hoses from wet tank to manifold valve assembly. Faulty air compressor or governor adjustment. Faulty wheel valve venting. Faulty manifold valve assembly relief valve. Faulty manifold valve assembly. Faulty quick release valve(s). Faulty rear axle quick release valve fittings. Faulty front quick release valve fittings. Faulty front tee fittings. Faulty manifold valve assembly delivery port fittings. Faulty cab floor supply hose fittings. Faulty supply hoses from quick release valve(s) to wheel valve(s). Faulty wheel valve filters. Faulty electrical connections at CTIS ECU and manifold valve assembly. Faulty CTIS ECU. Tighten loose air hoses. Replace damaged air hoses and/or fittings (para 23-2). m1. TWO STEADY MODE LIGHTS ILLUMINATE ON CTIS ECU (CONT) m1. TWO STEADY MODE LIGHTS ILLUMINATE ON CTIS ECU (CONT) m1. TWO STEADY MODE LIGHTS ILLUMINATE ON CTIS ECU (CONT) m1. TWO STEADY MODE LIGHTS ILLUMINATE ON CTIS ECU (CONT) m1. TWO STEADY MODE LIGHTS ILLUMINATE ON CTIS ECU (CONT)