TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 804 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1748 2-1748 2-1748 2-1748 2-1748 1. YES NO YES NO 2. Engine runs. Visual inspection START Visual inspection KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION j6. NOISY AIR COMPRESSOR OPERATION INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-365-10). Kinked compressor oil hoses. Kinked compressor coolant hoses. Loose or missing air compressor mounting hardware. Faulty air compressor. Kinked compressor coolant hoses will cause overheating and noisy compressor operation. Are air compressor coolant hoses free from kinks? Kinked compressor coolant hoses. Loose or missing air compressor mounting hardware. Faulty air compressor. Kinked compressor oil hoses will cause noisy air compressor operation. Are air compressor oil hoses free from kinks? Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) Replace air compressor oil hose(s). Replace air compressor coolant hose(s) (para 6-11). Air compressor oil hoses OK.