TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1134 2-1134 2-1134 2-1134 2-1134 START YES NO KNOWN INFO 1. INITIAL SETUP Equipment Condition Engine shut down (TM 9-2320-365-10). AC power connected (TM 9-2320-365-10). Personnel Required (2) Go to step 8 of this fault. Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) STE/ICE-R (Item 39, Appendix C) Multimeter, Digital (Item 22, Appendix C) References TM 9-4910-571-12&P POSSIBLE PROBLEMS TEST OPTIONS Visual inspection REASON FOR QUESTION This question helps eliminate possible problems and determines where troubleshooting continues. e104. M1079 LIGHTING FIXTURE(S) DS82 AND/OR DS83 DO NOT OPERATE Lighting fixtures DS80 and DS81 OK. Faulty fluorescent lamps. Faulty wire 706B. Faulty wire 1499K. Faulty wire 3085AJ. Faulty lighting fixture. Faulty wire 3085B. Does lighting fixture DS83 or DS82 operate?