TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 763 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1737 2-1737 2-1737 2-1737 2-1737 (1) Disconnect air hose from purge valve on air dryer. (2) Start engine (TM 9-2320-365-10). (3) Check for presence of air from air hose. (4) If air is steadily present from air hose and purge valve air has stopped, air compressor governor is defective. (5) Shut down engine (TM 9-2320-365-10). (6) Connect air hose to purge valve on air dryer. (1) Disconnect air hose on wet tank coming from air dryer. (2) Start engine (TM 9-2320-365-10). (3) Check for presence of air at air hose. If no air escapes from air hose, air hose is faulty. (4) If air escapes, service air dryer (para 23-6). (5) Shut down engine (TM 9-2320-365-10).