TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 756 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1730 2-1730 2-1730 2-1730 2-1730 1. YES NO YES NO 2. Nothing. Is dessicant cartridge clean? REASON FOR QUESTION Visual inspection Is purge valve clear? Dirty desiccant cartridge will cause dryer not to purge and will result in excess moisture in system. A blocked purge valve will cause dryer not to purge and will result in excess moisture in system. START Desiccant cartridge OK. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS Visual inspection KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION j2. LARGE QUANTITY OF MOISTURE EXPELLED FROM AIR RESERVOIRS INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-365-10). Dessicant cartridge dirty. Faulty air dryer purge valve. Blocked governor air hose. Faulty air compressor. Faulty air dryer purge valve. Blocked governor air hose. Faulty air compressor. Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) Goggles, Industrial (Item 15, Appendix C) Service air dryer (para 23-6). Service air dryer (para 23-6).