SOAPY WATER LEAK TEST (1) Apply soapy water solution to hoses, fittings, and couplings. (2) Check hoses and fittings for bubbles, indicating leaks. (1) Open wet tank drain cock and check for excessive amounts of moisture. (2) If moisture exists in wet tank, service air dryer desiccant (para 23-6). (3) Close wet tank drain cock. Change 1 2-1727 TM 9-2320-365-20-2