TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 75 of 1432
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2  2-1129 2-1129 2-1129 2-1129 2-1129  CONTINUITY TEST  (1) Loosen screw in terminal board TB3.  (2) Remove wire 3085C from terminal board  TB3.  (3) Set multimeter to ohms.  (4) Connect positive (+) probe of multimeter to  wire 3085C.  (5) Connect negative (-) probe of multimeter to  wire 3085AK and note reading on  multimeter.  (6) If continuity is not present, repair or replace  wire 3085AK between lighting fixtures DS80  and DS81 (para 2-40).  (7) If continuity is present, replace lighting fixture  DS81 (para 16-59).  (8) Install ballast cover on lighting fixture DS81.  (9) Install two fluorescent lamps in lighting  fixture DS81.  (10) Install tube lock holder at each end of two  fluorescent lamps.  (11) Install diffuser on lighting fixture DS81.  (12) Install wire 3085C on terminal board TB3.  (13) Tighten screw in terminal board TB3.  (14) Install cover on 110/208 VAC POWER  DISTRIBUTION PANEL with six screws.