TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 74 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1128 2-1128 2-1128 2-1128 2-1128 TEST OPTIONS REASON FOR QUESTION KNOWN INFO Continuity Test or STE/ICE-R #91 6. POSSIBLE PROBLEMS NO YES Lighting fixtures DS82 and DS83 OK. Lighting fixture DS80 OK. Fluorescent lamps OK. Wire 706B OK. Wire 1499J OK. Faulty wire 3085AK. Faulty lighting fixture DS81. Is continuity present from wire 3085C in 110/208 VAC POWER DISTRIBUTION PANEL to wire 3085AK in lighting fixture DS81? If continuity is not present, wire 3085C is faulty. If continuity is present, lighting fixture DS81 is faulty. Replace lighting fixture DS81 (para 16-59). Repair or replace wire 3085AK between lighting fixtures DS80 and DS81 (para 2-40). e103. M1079 LIGHTING FIXTURE(S) DS80 AND/OR DS81 DO NOT OPERATE (CONT) e103. M1079 LIGHTING FIXTURE(S) DS80 AND/OR DS81 DO NOT OPERATE (CONT) e103. M1079 LIGHTING FIXTURE(S) DS80 AND/OR DS81 DO NOT OPERATE (CONT) e103. M1079 LIGHTING FIXTURE(S) DS80 AND/OR DS81 DO NOT OPERATE (CONT) e103. M1079 LIGHTING FIXTURE(S) DS80 AND/OR DS81 DO NOT OPERATE (CONT)