TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1127 2-1127 2-1127 2-1127 2-1127 CONTINUITY TEST (1) Remove six screws and cover from 110/208 VAC POWER DISTRIBUTION PANEL. (2) Loosen screw in terminal board TB4. (3) Remove wire 1499J from terminal board TB4. (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter to wire 1499J in 110/208 VAC POWER DISTRIBUTION PANEL. (6) Connect negative (-) probe of multimeter to wire 1499J in lighting fixture DS81 and note reading on multimeter. (7) If continuity is not present, repair or replace wire 1499J between lighting fixtures DS80 and DS81 (para 2-40). (8) Install wire 1499J on terminal board TB4. (9) Tighten screw in terminal board TB4.