TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 72 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1126 2-1126 2-1126 2-1126 2-1126 TEST OPTIONS REASON FOR QUESTION KNOWN INFO Continuity Test or STE/ICE-R #91 YES NO POSSIBLE PROBLEMS 5. If continuity is not present, wire 1499J is faulty. Lighting fixtures DS82 and DS83 OK. Lighting fixture DS80 OK. Fluorescent lamps OK. Wire 706B OK. Faulty wire 1499J. Faulty wire 3085AK. Faulty lighting fixture DS81. Is continuity present from wire 1499J in 110/208 VAC POWER DISTRIBUTION PANEL to wire 1499J in lighting fixture DS81? Repair or replace wire 1499J between lighting fixtures DS80 and DS81 (para 2-40). e103. M1079 LIGHTING FIXTURE(S) DS80 AND/OR DS81 DO NOT OPERATE (CONT) e103. M1079 LIGHTING FIXTURE(S) DS80 AND/OR DS81 DO NOT OPERATE (CONT) e103. M1079 LIGHTING FIXTURE(S) DS80 AND/OR DS81 DO NOT OPERATE (CONT) e103. M1079 LIGHTING FIXTURE(S) DS80 AND/OR DS81 DO NOT OPERATE (CONT) e103. M1079 LIGHTING FIXTURE(S) DS80 AND/OR DS81 DO NOT OPERATE (CONT)