TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 715 of 1432

WARNING Wear appropriate eye protection when working under vehicle due to the possibility of falling debris. Failure to comply may result in injury to personnel. NOTE Air system pressure must be in the 90-120 psi operating range to begin brake system troubleshooting. If air pressure cannot be maintained within operating range, proceed to Air System Troubleshooting. TM 9-2320-365-20-2 Change 1 2-1691 (1) Loosen air hose 208 at foot control valve supply port 12 and listen for presence of escaping air. (2) If escaping air cannot be heard, replace air hose 208 (para 11-19). (3) Tighten air hose 208 on foot control valve supply port 12.