TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1125 2-1125 2-1125 2-1125 2-1125 CONTINUITY TEST (1) Open door on 110/208 VAC POWER DISTRIBUTION PANEL (TM 9-2320-365-10). (2) Position circuit breaker CB1 to OFF (TM 9-2320-365-10). (3) Remove two screws and cover from outlet box. (4) Remove ballast cover from lighting fixture DS81. (5) Set multimeter to ohms. (6) Connect positive (+) probe of multimeter to top left pole of INTERIOR LIGHTS switch S32. (7) Connect negative (-) probe of multimeter to wire 706B in lighting fixture DS81 and note reading on multimeter. (8) If continuity is not present, repair or replace wire 706B between lighting fixtures DS80 and DS81 (para 2-40). (9) Install cover on outlet box with two screws. (10) Close door on 110/208 VAC POWER DISTRIBUTION PANEL (TM 9-2320-365-10).