TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2  2-1123 2-1123 2-1123 2-1123 2-1123  CONTINUITY TEST  (1) Remove diffuser from lighting fixture DS81.  (2) Remove tube lock holder from each end of two  fluorescent lamps.  (3) Remove two fluorescent lamps from lighting  fixture DS81.  (4) Set multimeter to ohms.  (5) Connect positive (+) probe of multimeter to  one pin on end of fluorescent lamp.  (6) Connect negative (-) probe of multimeter to  other pin on same end of fluorescent lamp and  note reading on multimeter.  (7) Perform steps (5) and (6) on opposite end of  fluorescent lamp.  (8) If continuity is not present at either end of  fluorescent lamp, replace fluorescent lamp  (para 16-59).  (9) Perform steps (5) through (8) on second  fluorescent lamp.