TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2  2-1122 2-1122 2-1122 2-1122 2-1122  TEST OPTIONS  REASON FOR QUESTION  KNOWN INFO  Continuity Test or  STE/ICE-R #91  3.  YES  NO  Replace fluorescent lamps  (para 16-59).  POSSIBLE PROBLEMS If continuity is not present,  fluorescent lamps are  faulty.  Lighting fixtures DS82  and DS83 OK.  Lighting fixture DS80 OK.  Is continuity present  across pins at each end of  fluorescent lamps in  lighting fixture DS81? Faulty fluorescent lamps.  Faulty wire 706B.  Faulty wire 1499J.  Faulty wire 3085AK.  Faulty lighting fixture  DS81.  e103. M1079 LIGHTING FIXTURE(S) DS80 AND/OR DS81 DO NOT OPERATE (CONT) e103. M1079 LIGHTING FIXTURE(S) DS80 AND/OR DS81 DO NOT OPERATE (CONT) e103. M1079 LIGHTING FIXTURE(S) DS80 AND/OR DS81 DO NOT OPERATE (CONT) e103. M1079 LIGHTING FIXTURE(S) DS80 AND/OR DS81 DO NOT OPERATE (CONT) e103. M1079 LIGHTING FIXTURE(S) DS80 AND/OR DS81 DO NOT OPERATE (CONT)