TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 64 of 1432
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2  2-1118 2-1118 2-1118 2-1118 2-1118  START  YES  NO  TEST OPTIONS  REASON FOR QUESTION  KNOWN INFO  Visual inspection  1.  INITIAL SETUP  Equipment Condition  Engine shut down (TM 9-2320-365-10).  AC power connected (TM 9-2320-365-10).  Personnel Required  (2)  Go to step 8 of this fault.  This question helps  eliminate possible  problems and determines  where troubleshooting  continues.  Tools and Special Tools  Tool Kit, Genl Mech (Item 44, Appendix C)  STE/ICE-R (Item 39, Appendix C)  Multimeter, Digital (Item 22, Appendix C)  References  TM 9-4910-571-12&P  POSSIBLE PROBLEMS  e103. M1079 LIGHTING FIXTURE(S) DS80 AND/OR DS81 DO NOT OPERATE  Lighting fixtures DS82  and DS83 OK.  Faulty fluorescent lamps.  Faulty wire 706B.  Faulty wire 1499J.  Faulty wire 3085AK.  Faulty lighting fixture.  Faulty wire 3085C.  Does lighting fixture  DS80 or DS81 operate?