TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1117 2-1117 2-1117 2-1117 2-1117 (14) Install cover on INTERIOR LIGHTS switch S32 box with two screws. CONTINUITY TEST (1) Remove diffuser from light fixture DS80. (2) Remove tube lock holder from each end of two fluorescent lamps. (3) Remove two fluorescent lamps from light fixture DS80. (4) Remove ballast cover from light fixture DS80. (5) Set multimeter to ohms. (6) Connect positive (+) probe of multimeter to bottom left pole of INTERIOR LIGHTS switch S32. (7) Connect negative (-) probe of multimeter to fluorescent light DS80 wire 706B splice and note reading on multimeter. (8) If continuity is not present, repair or replace wire 706B (para 2-40). (9) If continuity is present, replace relay K41 (para 16-62). (10) Install ballast cover on light fixture DS80. (11) Install two fluorescent lights in light fixture DS80. (12) Install tube lock holder at each end of two fluorescent lamps. (13) Install diffuser on light fixture DS80.