TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 62 of 1432
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1116 2-1116 2-1116 2-1116 2-1116 TEST OPTIONS REASON FOR QUESTION KNOWN INFO Continuity Test or STE/ICE-R #91 5. POSSIBLE PROBLEMS NO YES If continuity is not present, wire 706B is faulty. If continuity is present, relay K41 is faulty. Is continuity present on wire 706B from INTERIOR LIGHTS switch S32 to fluorescent light DS80 wire 706B splice? Repair or replace wire 706B (para 2-40). 110 vac outlets OK. Circuit breaker CB6 OK. Wire 708BB OK. Wire 706C OK. INTERIOR LIGHTS switch S32 OK. Faulty wire 706B. Faulty relay K41. Replace relay K41 (para 16-62). e102. ALL M1079 FLOURESCENT LIGHTS DO NOT OPERATE (CONT) e102. ALL M1079 FLOURESCENT LIGHTS DO NOT OPERATE (CONT) e102. ALL M1079 FLOURESCENT LIGHTS DO NOT OPERATE (CONT) e102. ALL M1079 FLOURESCENT LIGHTS DO NOT OPERATE (CONT) e102. ALL M1079 FLOURESCENT LIGHTS DO NOT OPERATE (CONT)