TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 601 of 1432
TM 9-2320-365-20-2  Change 1 2-1596,9  CAUTION  CONTINUITY TEST  (1) Connect positive (+) probe of multimeter  to connector P116 socket 32.  (2) Connect negative (-) probe of multimeter to  connector PX33 socket P and note reading  on multimeter.  (3) Connect negative probe (-) of multimeter  to all other sockets in connector PX33,  one at a time, and note reading  on mutimeter.  (4) Connect negative probe (-) of multimeter  to ground and note reading on multimeter.  (5) If continuity is not present in step 2, or  continuity is present in step 3 or step 4,  repair wire 143 (para 2-40) or replace  WTEC III dashboard cable assembly  (para 7-11).  (6) Connect connector P116 to WTEC III  transmission ECU.  (7) Connect connector clamp on connector  P116.  NOTE  Use care when testing electrical connectors  not to bend connector pins or damage  connector sockets with multimeter probes.  Failure to comply may result in damage  to equipment.  Inspect connector pins/sockets for damage,  corrosion, and serviceability. Check that  connector pins are not pushed back and  are capable of making good contact.